NORDIC COMMERCIAL
IN Series Floor-ceiling units (Inverter)


DESCRIPTION:

  • Easy installation;
  • Self-diagnosis of malfunctions of the main blocks and modes;
  • Multilevel system protection;
  • Piping length up to 75 m. (for high power models).
R410A

MODELS:

Model CH-IF035NK/CH-IU035NK CH-IF050NK/CH-IU050NK CH-IF071NK/CH-IU071NK CH-IF100NK/CH-IU100NK CH-IF125NK/CH-IU125NM CH-IF140NK/CH-IU140NM CH-IF160NK/CH-IU160NM
Performance Cold kWh 3.5 5.2 7.15 10 12.02 14 15.4
Warm kWh 4 5.8 8 11 14 15 17
Power grid parameters ~220-2405V/
50Hz/1ph
~220-240V/
50Hz/1Ph
~220-2405V/
50Hz/1ph
~220-2405V/
50Hz/1ph
~220-2405V/
50Hz/1ph
~380-415V/
50Hz/1ph
~380-415V/
50Hz/3Ph
Power consumption Cold kWh 1.03 1.62 2.2 3.4 4.1 5 5.2
Warm kWh 1.2 1.7 2.4 3.2 4.1 4.4 4.8
Power current Cold А 4.45 7 16.3 7.1 8.6 9
Warm А 5.2 7.4 15.3 7.1 7.6 8.4
Energy efficiency Cold EER 3.4 3.21 3.21 2.94 2.93 2.8 2.96
Warm COP 3.3 3.41 3.33 3.44 3.42 3.41 3.54
Air capacity m³/hour
Sound pressure level Indoor unit dB (A)
Sound pressure level Outdoor unit dB (A) 51 55 55 58 59 60
Freon type
Refrigerant type R410A
Dimensions (WxDxH) Indoor unit mm 870/665/235 870/665/235 870/665/235 1200/665/235 1200/665/235 1570/665/235 1570/665/235
Outdoor unit mm 818/596/302 818/596/302 892/340/698 488/855/1083 940/820/460 940/820/460 940/820/460
Weight Indoor unit/ Outdoor unit Kg  37  /37  /53  61 90  /96 /100
Freon quantity Kg 1 1.25 2 2.45 3.4 3.7 3.8
Temperature range Cold °C -15 … +48 -15 … +48 -15 … +48 -15 … +48 -15 … +48 -15 … +48 -20 … +48
Warm °C -20 … +24 -20 … +24 -20 … +24 -20 … +24 -20 … +24 -20 … +24 -20 … +24
Liquid pipe line diameter mm/inch 6.38/1/4” 6.38/1/4” 9.53/3/8” 9.53/3/8” 9.53/3/8” 9.53/3/8” 9.53/3/8”
Gas line diameter mm/inch 9.53/3/8” 12.7/1/2” 15.88/5/8” 15.88/5/8” 15.88/5/8” 15.88/5/8” 15.88/5/8”
Maximum line height difference m 15 20 25 25 30 30 30
Maximum freon pipeline length m 30 35 50 50 65 75 75
Mounting distance of the bolts of the outdoor unit mm 550 550 560 610 610 610 660
Number of interblock cable cores (for controlling)
2 * 0.75 – with a length of 20 m
2 * 1.0 – with a length of more than 20 m
Main power supply point
Outdoor unit
Number of cable cores (for controlling indoor / outdoor units) Indoor unit 3(Ø1.0 mm) 3(Ø1.0 mm) 3(Ø1.0 mm) 3(Ø1.0 mm) 3(Ø1.0 mm) 3(Ø1.0 mm) 3(Ø1.0 mm)
Outdoor unit 3(Ø2.5 mm) 3(Ø2.5 mm) 3(Ø2.5 mm) 3(Ø4.0 mm) 3(Ø2.5 mm) 5(Ø1.5 mm) 5(Ø1.5 mm)
Number of freon refueling per r.m. (excess, for each r.m)  m 5 5 5 5 5 7.5 7.5
Factory refrigerant charge volume (for the number of running meters) gr/r.m. 22 22 30 30 35 50 50