DESCRIPTION:
- Easy installation;
- Compact dimensions;
- Low noise fan;
- Long lasting washable filter;
- Effective heat dissipation of the indoor unit;
- Self-diagnosis of malfunctions of the main blocks and modes;
- Protection against incorrect power connection;
- Pipe length up to 50 m. (for high power models).
MODELS:
Model | CH-D18NK2/CHU18NK2 | CH-D24NK2/CHU24NK2 | CH-D36NK2/CHU36NM2 | CH-D48NK2/CHU48NM2 | CH-D60NK2/CHU60NM2 | ||
---|---|---|---|---|---|---|---|
Performance | Cold | kWh | 5 | 7 | 10 | 14 | 16 |
Warm | kWh | 5.4 | 7.4 | 11.5 | 15 | 18 | |
Power supply | ~ 220-240V/ 50Hz/1Ph |
~ 220-240V/ 50Hz/1Ph |
~ 220-240V/ 50Hz/1Ph |
~ 220-240V/ 50Hz/1Ph |
~ 220-240V/ 50Hz/1Ph |
||
Rated power consumption | Cold | kWh | 2 | 2.5 | 2.5 | 2.5 | 2.5 |
Warm | kWh | 1.9 | 2.35 | 2.35 | 2.35 | 2.35 | |
Current strength | Cold | А | 9.2 | 12 | 12 | 12 | 12 |
Warm | А | 8.2 | 10.5 | 10.5 | 10.5 | 10.5 | |
Energy efficiency | Cold | EER | 2.5 | 2.8 | 2.8 | 2.8 | 2.8 |
Warm | COP | 2.84 | 3.23 | 3.23 | 3.23 | 3.23 | |
Air capacity | m3/hour | 720/660/540/420 | 1265/1000/780/660 | 1265/1000/780/660 | 1265/1000/780/660 | 1265/1000/780/660 | |
Pressure range | Indoor units | Pa | 0-30 | 0-40 | 0-40 | 0-40 | 0-40 |
Sound pressure level | Indoor unit / Outdoor unit | dB (A) | 36/33/30/29 56 | 46/44/42/36/59 | 46/44/42/36/59 | 46/44/42/36/59 | 46/44/42/36/59 |
Refrigerant type | |||||||
Dimensions (WxDxH) | Indoor unit / Outdoor unit | mm | 1015х275х720/ 955х700х395 | 1260х270х555/ 955х700х395 | 1260х270х555/ 955х700х395 | 1260х270х555/ 955х700х395 | 1260х270х555/ 955х700х395 |
Indoor unit / Outdoor unit | Kg | 31/53 | 33/61 | 33/61 | 33/61 | 33/61 | |
Kg | 1.3 | 1.5 | 1.5 | 1.5 | 1.5 | ||
Operating temperature range | Cold | °C | -15 … +43 | -15 … +43 | -15 … +43 | -15 … +43 | -15 … +43 |
Warm | °C | -10 … +24 | -10 … +24 | -10 … +24 | -10 … +24 | -10 … +24 | |
Liquid pipe line diameter | mm/inch | 6.35/1/4″ | 9.53/ 3/8’’ | 9.53/ 3/8’’ | 9.53/ 3/8’’ | 9.53/ 3/8’’ | |
Gas line diameter | mm/inch | 12.70/1/2″ | 15.88/5/8″ | 15.88/5/8″ | 15.88/5/8″ | 15.88/5/8″ | |
Maximum line height difference | m | 15 | 15 | 15 | 15 | 15 | |
Maximum freon pipeline length | m | 15 | 15 | 15 | 15 | 15 | |
Distance between bolts of fastening of outdoor unit | mm | 560 | 560 | 560 | 560 | 560 | |
Plokkidevahelise kaabli soonte arv | |||||||
Main power supply point | Outdoor unit | Outdoor unit | Outdoor unit | Outdoor unit | |||
Number of cable cores (power supply) | Indoor units | 3(Ø1.0 mm)/ | 3(Ø1.0 mm)/ | 3(Ø1.0 mm)/ | 3(Ø1.0 mm)/ | 3(Ø1.0 mm)/ | |
Outdoor unit | 3(Ø4.0 mm) | 3(Ø4.0 mm) | 3(Ø4.0 mm) | 3(Ø4.0 mm) | 3(Ø4.0 mm) | ||
Number of freon refueling per r.m. (excess, for each r.m) | r.m. | 7 | 7 | 7 | 7 | 7 | |
Number of freon refueling per r.m. (excess, for each r.m) | gr/r.m. | 15 | 60 | 60 | 60 | 60 |